The AERIO-X hydrogen sensor
AX-H2-01
Sensitive hydrogen detection.
Low sensing power.
A printable sensing element for hydrogen in air, combining heater-free operation with a tunable response.
- Heater-free operationMeasure hydrogen at room temperature without a heater.
- Tunable responseMatch the sensing response to your application.
- Readout integrationConnect to external electronics for your test setup or monitoring network.
Target performance
≤ 0.2 ppm
Calculated detection limit
< 1 s
Response time
≤ 2 µW
Sensing-element power
AX-H2-01
Technical specifications
| Parameter | Value | Conditions |
|---|---|---|
| Measurement range | Tunable | Configured for the application. |
| Detection limit | ≤ 0.2 ppm | Calculated; 20 °C · 15% RH · 1 V. |
| Response time | < 1 s | 10–90% change; 1% H₂ · 20 °C · 60% RH · 0.5 V. |
| Recovery time | ≤ 7 s | 90–10% change in air; 1,000 ppm H₂ · 20 °C · 15% RH · 0.5 V. |
| Sensing-element power | ≤ 2 µW | 20 °C · 15% RH; external readout required. |
| Element bias | 0.5–1 V | Reference operating points. |
| Tested temperature | 20–120 °C | Response decreases above 40 °C. |
| Tested humidity | 15–80% RH | At 20 °C; response depends on bias and humidity. |
| Measurement environment | Hydrogen in air | Oxygen is needed for recovery. |
IntegrationStart with your
Start with your
measurement needs.
Tell us the concentrations and conditions you need to monitor. We’ll help you assess sensor fit and readout integration.
What to consider
- Hydrogen concentration and exposure duration
- Background gases, solvent vapours and humidity
- Ambient air availability for recovery
- Readout, power budget and measurement locations
Discuss AX-H2-01 for your project.